參數(shù)/Parameters |
條件/Condition |
規(guī)格/Specs |
單位/Units |
||||
Min |
Typ |
Max |
|||||
通道數(shù)/Number of Channels |
|
40 |
|
||||
通道間距/Number Channel Spacing |
100GHz |
100 |
GHz |
||||
中心波長/Cha. Center Wavelength |
ITU頻率/ITU frequency. |
C -band |
nm |
||||
通帶頻率/Clear Channel Passband |
|
±0.1 |
nm |
||||
波長精度/Wavelength Stability |
Maximum range of the wavelength error of all channels and temperatures in average polarization. |
±0.05 |
nm |
||||
-1 dB帶寬/-1 dB Channel Bandwidth |
Clear channel bandwidth defined by passband shape. For each channel |
0.4 |
|
|
nm |
||
-3 dB帶寬/-3 dB Channel Bandwidth |
Clear channel bandwidth defined by passband shape. For each channel |
0.6 |
|
|
nm |
||
插損/Optical Insertion Loss at ITU grid |
Defined as the minimum transmission at ITU wavelength for all channels. For each channel, at all temperatures and polarizations. |
|
4.5 |
6.0 |
dB |
||
相鄰通道隔離度/Adjacent Channel Isolation |
Insertion loss difference from the mean transmission at the ITU grid wavelength to thehighest power, all polarizations, within the ITU band of the adjacent channels. |
25 |
|
|
dB |
||
非相鄰通道隔離度/Non-Adjacent, Channel Isolation |
Insertion loss difference from the mean transmission at the ITU grid wavelength to thehighest power, all polarizations, within the ITU band of the nonadjacent channels. |
30 |
|
|
dB |
||
總隔離度/Total Channel Isolation |
Total cumulative insertion loss difference from the mean transmission at the ITU grid wavelength to the highest power, all polarizations, within the ITU band of all other channels, including adjacent channels. |
22 |
|
|
dB |
||
插損一致性/Insertion Loss Uniformity |
Maximum range of the insertion loss variation within ITU across all channels, polarizations and temperatures. |
|
1.0 |
1.5 |
dB |
||
方向性Directivity(Mux Only) |
Ratio of reflected power out of any channel(other than channel n)to power in from the input channel n |
40 |
|
|
dB |
||
插損平坦度/Insertion Loss Ripple |
Any maxima and any minima of optical loss across ITU band, excluding boundary points, for each channel at each port |
|
|
0.5 |
dB |
||
回損/Optical Return loss |
Input & output ports |
40 |
|
|
dB |
||
PDL/Polarization Dependent Loss in Clear Channel Band |
Worst-case value measured in ITU band |
|
0.3 |
0.5 |
dB |
||
偏振模式色散/Polarization Mode Dispersion |
|
|
|
0.5 |
ps |
||
最大承受光功率/Maximum Optical Power |
|
|
|
23 |
dBm |
||
功率監(jiān)控范圍/MUX/DEMUX input/ output Monitoring range |
|
-35 |
|
+23 |
dBm |
||
本網(wǎng)頁所展示的有關(guān)【40CH AWG DWDM 密集波分復(fù)用器_光纖波分復(fù)用器_珠海飛宇光電科技有限公司】的信息/圖片/參數(shù)等由商一網(wǎng)的會(huì)員【珠海飛宇光電科技有限公司】提供,由商一網(wǎng)會(huì)員【珠海飛宇光電科技有限公司】自行對信息/圖片/參數(shù)等的真實(shí)性、準(zhǔn)確性和合法性負(fù)責(zé),本平臺(tái)(本網(wǎng)站)僅提供展示服務(wù),請謹(jǐn)慎交易,因交易而產(chǎn)生的法律關(guān)系及法律糾紛由您自行協(xié)商解決,本平臺(tái)(本網(wǎng)站)對此不承擔(dān)任何責(zé)任。您在本網(wǎng)頁可以瀏覽【40CH AWG DWDM 密集波分復(fù)用器_光纖波分復(fù)用器_珠海飛宇光電科技有限公司】有關(guān)的信息/圖片/價(jià)格等及提供【40CH AWG DWDM 密集波分復(fù)用器_光纖波分復(fù)用器_珠海飛宇光電科技有限公司】的商家公司簡介、聯(lián)系方式等信息。